The PLA-ZRP Power Inverter heat pump series offer customers high seasonal efficiency, advanced control options and quit operation, whilst providing greater flexibility and ease of installation.
|
Heating nominal capacity | 11.2 (4.5-14.0) |
Cooling nominal capacity | 10.0 (4.9-11.4) |
Heating (UK) capacity | 9.5 (3.85-11.9) |
Cooling (UK) capacity | 9.2 (4.5-10.5) |
SHF (Nominal & UK) | 0.74 |
COP / EER Nominal | 4.29 / 3.85 |
SCOP / SEER (BS EN14825) | 4.6 / 6.5 |
Heating ErP energy efficiency class | A++ |
Cooling ErP energy efficiency class | A++ |
Air flow (m3/min) | 20-23-26-30 |
Gas pipe size | 5/8″ |
Liquid pipe size | 3/8″ |
Sound pressure level (dBA) | 32-34-37-40 |
Sound power level (dBA) | 65 |
Dimensions (mm) | 840 (950) x 840 (950) x 258 (35) |
Weight Unit / Panel (kg) | 26 / 6 |
Electrical supply Fed by | Outdoor unit |
Fuse rating HRC (A) | 6 |
Interconnecting cable No. cores | 4 |
Panel reference | PLP-6BA |
Wired remote controller reference | PAR-31MAA |
Heating sound pressure level (dBA) | 51 |
Cooling sound pressure level (dBA) | 49 |
Cooling sound power level (dBA) | 69 |
Weight (kg) | 124 |
Dimensions (W x D x H) | 1050 x 330 + 30 x 1338 |
Electrical supply | 380-415 V, 50 Hz |
Phase | Three |
Nominal heating system power input (kW) | 2.61 |
Nominal cooling system power input (kW) | 2.60 |
Nominal UK heating system power input (kW) | 2.32 |
Nominal UK cooling system power input (kW) | 2.21 |
Starting Current (A) | 4.0 |
Heating system running current (A) | 4.82 |
Cooling system running current (A) | 4.84 |
MAX system running current (A) | 8.7 |
Fuse rating (BS88) (A) | 16 |
Mains cable no cores | 5 |
MAX pipe length (m) | 75 |
MAX high difference (m) | 30 |
Charge R410A (kg) | 5.0 (30m) |
Reviews
There are no reviews yet.